Fire safety information for residents: what you must give them
Quick answer
If you're the responsible person for a building in England with two or more flats and shared escape routes, you must give every resident fire safety instructions (Regulation 9) and fire door information (Regulation 10). Give it to new residents as soon as reasonably practicable after they move in, to all residents at least every 12 months and after any material change, and display the instructions in a conspicuous part of the building.
If you're the responsible person for a block of flats in England, the law requires you to give residents fire safety instructions and information about fire doors, and to repeat it at least every 12 months. This guide explains what the Fire Safety (England) Regulations 2022 require, how the duties vary with building height, what to include, and how to evidence that you've done it.
Fire safety law for blocks of flats
- The Regulatory Reform (Fire Safety) Order 2005 is the main fire safety law for the common parts of blocks of flats. It places duties on the “responsible person” and is enforced by the local fire and rescue authority.
- The Fire Safety Act 2021 confirmed that the Order also covers the building's structure, external walls (including windows and balconies) and flat entrance doors.
- The Fire Safety (England) Regulations 2022, in force since 23 January 2023, add specific duties. Regulation 9 covers fire safety instructions, and Regulation 10 covers fire doors.
- Section 156 of the Building Safety Act 2022 added further duties from 1 October 2023, including recording your fire risk assessment in full and giving residents information about the risks it found, the fire safety measures in place, and who is responsible.
Which buildings and residents it applies to
- Buildings in England with two or more flats and common parts that residents would use to evacuate in a fire. There's no minimum height: a converted house with two flats and a shared hallway can be covered.
- The responsible person. For a block of flats, that's usually the freeholder, the residents' management company or right to manage company, or a managing agent or block manager acting for them.
- Every resident, whether they own or rent their flat.
Fire safety instructions (Regulation 9)
You must give residents instructions, in a comprehensible form they can reasonably be expected to understand, covering:
- the evacuation strategy for the building;
- how to report a fire to the fire and rescue service; and
- anything else residents must do once a fire has happened.
The evacuation strategy must match your building's fire risk assessment. The common strategies are:
- Stay put (defend in place): residents not directly affected by fire or smoke stay in their flat, relying on the fire-resisting construction between flats. Used in most purpose-built blocks.
- Simultaneous evacuation: everyone leaves when the fire alarm sounds. Used in some converted buildings and where compartmentation can't be relied on.
- Temporary simultaneous evacuation: an interim change from stay put, usually while defects such as unsafe external walls are fixed, supported by a common fire alarm or a waking watch.
You must also display the instructions in a conspicuous part of the building, such as the main entrance lobby, and update both the display and residents' copies after any material change.
For more on the most common strategy, see stay put policy in blocks of flats.
Fire door information (Regulation 10)
Residents must be told that:
- fire doors should be kept shut when not in use;
- residents and their guests should not tamper with the self-closing devices on fire doors; and
- residents should report any fault or damage to fire doors straight away to the responsible person.
It helps to explain why. Flat entrance doors and communal fire doors are typically FD30S doorsets: tested to resist fire for 30 minutes, with smoke seals to limit the spread of cold smoke. With a self-closing device, they keep escape routes usable and protect each flat as a separate compartment. But a doorset only performs as tested if it closes fully into its frame, with its intumescent strips, smoke seals, hinges and closer intact.
Encourage residents to report:
- a door that doesn't close fully by itself, or slams;
- damaged or missing intumescent strips or smoke seals;
- gaps around the door that look larger than usual; and
- any alterations, such as a new letterbox, spy hole or cat flap, or a replacement door fitted without approval.
Fire safety information (section 156)
Since 1 October 2023, article 21A of the Fire Safety Order has also required you to give residents comprehensible and relevant information about:
- the risks to residents identified by your fire risk assessment;
- the preventive and protective measures in place, such as fire doors, emergency lighting and smoke alarms;
- the name of the responsible person, and a UK address where they, or someone acting for them, will accept notices and other documents;
- the identity of anyone appointed to help make or review the fire risk assessment;
- anyone nominated to carry out fire-fighting measures; and
- any risks another responsible person in the building has told you about.
When to give residents fire safety information
- To new residents, as soon as reasonably practicable after they move in.
- To all residents, at least once every 12 months.
- Again, after any material change to the fire safety instructions.
Many responsible persons issue the pack on a fixed date each year, so every resident is covered within the 12-month window, and give it to new residents when they get their keys.
Reaching every resident
The duty is to give the information in a form residents can reasonably be expected to understand. In practice, that means:
- posting or hand-delivering a printed copy to every flat, and emailing it where you have an address;
- offering translations or other formats, such as large print, where residents need them;
- asking landlords of rented flats to pass it to their tenants, and checking that they have; and
- making sure residents who may need help to evacuate know how to tell you. From 6 April 2026, residential personal emergency evacuation plans apply to high-rise buildings, and to buildings over 11 metres with a simultaneous evacuation strategy.
See residential PEEPs for blocks of flats for what the 2026 rules require.
Taller buildings have extra duties
- Over 11 metres (measured to the floor of the top storey): check the fire doors in the common parts at least every 3 months, and use best endeavours to check flat entrance doors at least once a year.
- 18 metres or more, or 7 or more storeys: further duties, including building plans and a secure information box for the fire and rescue service, wayfinding signage, monthly checks of firefighting lifts and equipment, and residential personal emergency evacuation plans.
Enforcement by the fire and rescue authority
Your local fire and rescue authority enforces these duties. It can inspect, ask to see your fire risk assessment and records, serve enforcement notices, and prosecute. Serious breaches of fire safety law can lead to unlimited fines and, in the worst cases, up to two years in prison.
Keep a record of what you've given residents
Keep an audit trail of when each flat received the information and how, when the instructions were displayed, and when they were last updated. If your building is over 11 metres, also record your fire door checks, including attempts to get access to flat entrance doors where residents didn't let you in: that's how you show best endeavours. A clear record lets you show the fire and rescue authority what you've done.
How Resident Fire Safety helps
Enter your building's details once. Resident Fire Safety produces the resident leaflet and the notice for your common parts, using wording built around Regulations 9 and 10 and tailored to your evacuation strategy. It keeps a flat-by-flat record of issue, and flags when the next pack is due.
It costs £59 per building per year, whatever the number of flats, with unlimited updates and re-downloads. See pricing
The leaflet also covers the section 156 information: the main risks your fire risk assessment found, the fire safety measures in the building, who carried out the assessment, and the responsible person's name and UK address. Resident Fire Safety doesn't replace a fire risk assessment: the evacuation strategy, risks and measures must all come from yours.
For a summary you can keep, download our free fire safety guide for blocks of flats.
Sources: The Fire Safety (England) Regulations 2022, Regulatory Reform (Fire Safety) Order 2005, Fire Safety Act 2021, Building Safety Act 2022, section 156, The Fire Safety (Residential Evacuation Plans) (England) Regulations 2025
Common questions
Is fire door safety information for residents a legal requirement?
Yes, in England. Under the Fire Safety (England) Regulations 2022, residents of buildings with two or more flats must be told to keep fire doors shut, not to tamper with self-closing devices, and to report faults or damage to the responsible person.
Can I email the information instead of printing it?
The regulations don't say how it must be given, as long as each resident receives it in a form they can understand. Many responsible persons post or hand out a printed leaflet and also email it.
What if a resident's first language isn't English?
The instructions must be in a form residents can reasonably be expected to understand, so consider translations or other formats where needed.
What counts as a material change?
Anything that changes what residents need to do in a fire, for example a switch from stay put to simultaneous evacuation, a new fire alarm system, or a change to escape routes or the assembly point. Update the displayed instructions and reissue residents' copies straight away.
Do residents have to sign to say they've received it?
No, the regulations don't require a signature. But a record of when and how each flat received the information is good evidence if the fire and rescue authority asks.